Operating instructions for Additional Heater

For some Outdoor kiosks, an additional heater can be fitted to the locker area. These are the operating instructions you will need.

Written by Jason Dwight

All controls are located on this end of the heater, so you will need to set up your heater before mounting to the kiosk.

If your heater is already fitted, you will need to unscrew from the 4 mounting points to access the controls.

Indicator and button description:

  • Green indicator: power indicator, heater power on.

  • Red indicator: Always on when heating, blinking when ONLY cooling air supply, off means stopping heating

  • Up key : Press and hold this key to enter the upper limit adjustment function.

  • Down key: Press and hold this key to enter the lower limit temperature adjustment function.

Parameter setting:

  1. Control temperature upper limit adjustment: Press and hold the up button for more than 2 seconds to enter the control temperature upper limit adjustment function. At this time, the digital will flash "H XX" alternately, press the up key or down key to complete the setting. Save the Settings after 5 seconds, and the next time it will work as the setting automatically (the same below)

  2. Control temperature lower limit adjustment: Press and hold the down button for more than 2 seconds to enter the control temperature lower limit adjustment function, at this time the digital will flash "L XX" alternately, if the control temperature is lower than 0° C, it will alternately display "L-XX", press the up or down key to complete the setting.

  3. Press and hold the up key "A" and down key "" at the same time for more than 2 seconds, the heater setting parameters will be restored to the factory Settings.

  4. Adjust code specification:

CODE

FUNCTION

RANGE

FACTORY DEFAULT

REMARK

h

Temperature upper limit

-25~50

-10

Above this temperature, the heater stops heating

L

Temperature lower limit

-40~35

-15

Below this temperature, the heater starts heating

Heating operation:

When the ambient temperature is lower than the lower limit of the control temperature, the heater starts to heat until the ambient temperature reaches the upper limit of the control temperature. The fan continues to supply air to ensure that the heater is reliably cooled. When the space temperature falls below the lower limit of the control temperature again, the previous control process automatically restarts.